back to overview ▲

» DVM Test Report: Transient|LineSurge|HL_Maximum_to_HL_Surge|F_High|Light Load

Test Details
Schematic DVM_PFC_Continuous_Conduction_Mode.sxsch
Test Transient|LineSurge|HL_Maximum_to_HL_Surge|F_High|Light Load
Date / Time 12/10/2015 6:33 PM
Report Directory ac_dc_built_in\Transient\LineSurge\HL_Maximum_to_HL_Surge\F_High\LightLoad
Log File report.txt
Screenshot schematic.png
Status PASS
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
Frequency(Line) 60
ILine
MIN
-755.816m
MAX
862.048m
RMS
181.394m
ILine After Surge
MAX
400.696m
ILine During Surge
MAX
862.048m
RMS
265.716m
IPFCOutput
MIN
99.2674m
MAX
101.296m
Overshoot_VPFCOutput 405.182
VLine
MIN
-413.988
MAX
413.999
VLine After Surge
RMS
265
VLine During Surge
RMS
293
vout1_recovery_time_2 never left regulation
VPFCOutput
MIN
397.07
MAX
405.182
VPFCOutput %_diff_last_2_linecycles 0.00345922%
VPFCOutput After Surge
MIN
397.07
VPFCOutput At Simulation Start Time
AVG
400.096
VPFCOutput During Surge
MAX
405.182
VPFCOutput Last LineCycle
AVG
400.062
VPFCOutput overshoot
MAX
402.382
VPFCOutput Previous LineCycle
AVG
400.048
VPFCOutput_in_reg
AVG
399.977
MIN
398.796
MAX
400.814
RMS
399.977
PK2PK
2.01824
Measured Spec Values
AC_Settling(PFCOutput) PASS: Voltage across PFCOutput has settled to (34.5922u) % and is less than or equal to Max Settling Spec of (10m) %
Max_VPFCOutput_in_reg PASS: Max. Output1 Voltage in Reg. (400.814) is less than or equal to Max. Output1 Voltage Spec (420)
Min_VPFCOutput_in_reg PASS: Min. Output1 Voltage in Reg. (398.796) is greater than or equal to Min. Output1 Voltage Spec (380)
Overshoot_VPFCOutput PASS: Max. Output1 Voltage (405.182) is less than or equal to Max. Output1 Voltage Spec (420)
Pk2Pk_VPFCOutput_in_reg PASS: Pk-to-Pk Output1 Voltage in Reg. (2.01824) is less than or equal to Max. Output1 Voltage Spec (10)
PFCOutput
VPFCOutput
IPFCOutput
SXGPH File simplis_tran14_319.sxgph
Line
VLine
ILine
SXGPH File simplis_tran14_324.sxgph
Other SXGPH Files
AC#tran simplis_tran14_313.sxgph