back to overview ▲

» DVM Test Report: Transient|FindACSteadyState|HL_Maximum|F_Low|Enabled|100% Load

Test Details
Schematic DVM_PFC_Continuous_Conduction_Mode.sxsch
Test Transient|FindACSteadyState|HL_Maximum|F_Low|Enabled|100% Load
Date / Time 12/10/2015 6:21 PM
Report Directory ac_dc_built_in\Transient\FindACSteadyState\HL_Maximum\F_Low\Enabled\100%Load
Log File report.txt
Screenshot schematic.png
Status PASS
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
Frequency(Line) 50
ILine
MIN
-1.1732
MAX
1.1732
IPFCOutput
MIN
494.094m
MAX
506.096m
VLine
MIN
-374.368
MAX
374.368
RMS
265
VPFCOutput
MIN
395.275
MAX
404.877
VPFCOutput %_diff_last_2_linecycles 0.0000000792304%
VPFCOutput At Simulation Start Time
AVG
400.097
VPFCOutput Last LineCycle
AVG
400.097
VPFCOutput Previous LineCycle
AVG
400.097
Measured Spec Values
AC_Settling(PFCOutput) PASS: Voltage across PFCOutput has settled to (792.304p) % and is less than or equal to Max Settling Spec of (10m) %
Max_VPFCOutput PASS: Max. Output1 Voltage (404.877) is less than or equal to Max. Output1 Voltage Spec (420)
PFCOutput
VPFCOutput
IPFCOutput
SXGPH File simplis_tran2_27.sxgph
Line
VLine
ILine
SXGPH File simplis_tran2_32.sxgph
Other SXGPH Files
AC#tran simplis_tran2_21.sxgph